www.Droit-Afrique.com
Art.D.170-27.- Scaffolds, gangways, cantilevered
floor, elevated platforms, as well as their respective
access ways must have strong rigid balustrades
placed at a height of 90 centimetres.
The flying bridges or gangways used to load or
offload vessels shall have to form a rigid whole and
have rigid 90 centimetres high parapets on both
sides.
Art.D.170-28.- Wells, hatches,
vats, tanks,
reservoirs, pits and descending openings shall have
to be built, installed or protected in conditions that
ensure workers' safety.
Appropriate measures should protect workers from
risks of spillage or splashing, as well from risk of
pouring over the walls of vats, tanks, reservoirs,
carboys or canisters containing products capable of
causing thermally-induced burns.
Art.D.170-29.- Maintenance ladders should be
placed or fastened such that they cannot slip from
below or fall over. Rungs shall have to be rigid,
spaced out equally and embedded into the stiles.
Considering the weight to be borne and presence of
all the rungs, only sufficiently resistant ladders may
be used.
It shall be prohibited to use rungs to transport loads
weighing over 50kg. The stiles of double ladders
must, during their use, be fixed or coupled using a
rigid device.
Art.D.170-30.- Workers who are called upon to
work in wells, pipes, sewage pits, tanks or any
equipment that contains poisonous gases shall have
to wear a safety belt.
Art.D.170-31.- Lifting equipment, such as lifts and
station lifts, whose booths or platforms move in
between guide rails or vertical or sensibly vertical
guides shall be installed and built such that workers
do not run the risk of falling into the void, being hit
by a fixed or moving object, or in the event an
object falls, being hit by it.
Art.D.170-32.-The counterweights of lifting
equipment should be installed such that there is no
risk
Implementing Decree of the Labour
Code
Mali
of collision with the booth or fall from it.
Art.D.170-33.- The head of the institution shall
have to, under his/her responsibility, examine on a
daily basis the state of safety devices and the proper
functioning of lifting equipment.
He/she shall be obliged to ensure that the equipment
is serviced and lubricated, inspect the hoisting ropes
and lifting chains every six months and the safety
parts once every year.
The name and title of those tasked with this
servicing, the inspection dates and the remarks
made in the wake of these activities shall be
recorded in a register made available to the labour
inspector.
Art.D.170-34.- All lifting equipment should visibly
bear a statement from the manufacturer on the
maximum or standard weight that the equipment can
lift.
Art.D.170-35.- Any machine with a defect that
could cause an accident should be inspected at least
once quarterly.
These inspections shall be conducted by a specialist,
appointed for this purpose by the head of the
institution and answerable to the latter.
The results of the inspections shall be recorded in a
register known as “safety register” opened by the
head of the institution and constantly made available
to the labour inspector.
Art.D.170-36.- Rooms housing generators and
alternators shall be accessible only to workers
assigned to operate and service these machines.
In instances where these machines are not found in
separate premises, they shall be isolated using rigid
protective partitions or barriers, which are at least
90cm high.
Art.D.170-37.- An agreed sign must always be
given before machines powered by one command
are collectively launched and stopping.
Art.D.170-38.- The apparatus to stop alternators
must always be placed outside the dangerous area
and such that those operating these machines can
easily and immediately start it.
20/29
Sélectionner le paragraphe cible3
Se connecter à un paragraphe
Connect to an entity
Disable highlights
Ajouter à la table des matières