Art.D.170-18.- Premises where the flammable
substances in the first group are stored or handled
may be lit using only external lamps placed behind
framed glass.
They shall not contain any fireplace, no flame, no
equipment that can result in the external production
of sparks or having parts capable of becoming
incandescent.
They must be perfectly ventilated.
It shall be strictly prohibited to smoke in there: a
notice in clearly-visible characters or a symbol
pointing to this ban shall have to be put up there in.
Art.D.170-19.- In premises where flammable
substances in the first or second group are stored or
handled, no routine work station should be found
more than ten metres from an exit.
Mali
with daylight and on the condition that no fireplace
therein is lit.
Pipes taking combustible liquids or gases to fixed
lighting and heating appliances should be made of
metal completely.
Flames from portable heating or lighting appliances
should be placed at least one metre vertically and
0.30 metres laterally from any combustible part of
the building, furniture or deposited goods ; these
distances may be reduced if a non-combustible
screen, which does not touch the wall to be
protected, is placed between the said wall and the
flame.
Art.D.170-21.- Portable lighting appliances other
than electric lighting appliances must have a stable
and solid support.
The windows of these premises should be easy to
open from the inside out.
Fixed or portable lighting appliances should be
equipped with a glass, a globe, a wire mesh web or
any other device meant to prevent the flame from
coming into contact with flammable substances.
It shall be prohibited to place and allow
inflammable substances in the first or second group
in the staircase, passages or corridors or under
staircases as well as near the exits of premises and
buildings.
Lighting appliances found in passages should not
soil the walls or should be found at least two metres
from the floor.
Mobile containers of over two litres containing
flammable liquids in the first or second group
should be leak tight; if they are made of glass, they
shall have a metallic envelope, which is also leak
tight.
Foam, cotton, paper, steeped in flammable liquids
or fatty substances shall, after use, have to be kept
in closed and leak-tight metallic containers.
Art.D.170-20.- For lighting and heating, it shall be
prohibited to use any liquid that produces
flammable vapours above 35º centigrade if the
equipment used for this liquid is not placed in a
manner as to prevent the personnel from coming
into contact with it and if the part of this equipment
containing the liquid is not perfectly leak tight.
When the personnel is present, filling heating
appliances that use liquid combustibles and lighting
appliances either in work premises, passages or
staircases used for movement, may be done only
Fry pans, naked fire-producing appliances, pipes
and chimneys shall be installed so as to avoid
directly connecting the fire to the building,
substances or objects found nearby, or the cloths of
personnel.
Art.D.170-22.-Institutions shall have to place exits
and open spaces judiciously spread out to ensure the
rapid evacuation of personnel and customers in the
event of a fire.
The exits of premises and building may not and
notably may never be cluttered with goods or any
objects whatsoever.
The exits of premises or buildings may never be less
than two in number when they have to be used as a
passage by more than one hundred people, whether
or not these people belong to the institution's
workforce. This number shall be increased by a one
unit for every five hundred people or a fraction of
the first five hundred.
The width of the exits shall never be less than 80
centimetres.
The length of all the exits shall not be less than:
Implementing Decree of the Labour
Code
18/29